Prices and models of Orlando batteries D12-26/12V26Ah
Price:Negotiable
Contact Info
- Add:Room 313, 3rd Floor, Building 1, No. 4 Courtyard, Fuze Road, Fangshan District, Beijing, Zip: 10000
- Contact: 胡祥飞
- Tel:17662238989
- Email:zxc123321_0823@qq.com
Other Products
Description
Additional Information
Basic Information
- Model: D12 - 26.
- Type: Lead-acid maintenance-free battery 5.
- Rated Voltage: 12V 2.
- Rated Capacity: 26Ah (20-hour rate) 2.
Product Features
- Long Service Life Design: Adopting advanced grid manufacturing technology, the corrosion resistance of the grid has been greatly improved, and the floating charge service life can reach more than 10 years 1.
- Excellent High-rate Discharge Performance: Adopting cutting-edge plate and terminal design, combined with advanced formulas and welding technology, while ensuring capacity, it improves high-power discharge performance, and can meet the requirements of some equipment that demand instantaneous high-current discharge 1.
- High Safety: The battery case and cover are made of UL 94-V0 compliant flame-retardant materials, which can effectively prevent fires and other safety hazards, making the use safer and more secure 1.
- Low Self-discharge Rate: At room temperature of 20℃, after standing for 28 days, the self-discharge rate of the battery is less than 2%, which is higher than the industry standard requirements, and can maintain a relatively high power reserve during long-term storage 1.
- High Consistency: Through automated production processes with high production efficiency, the consistency of plates and batteries is good, making it more suitable for multi-cell series applications in UPS, and ensuring the stability of the performance of the entire battery pack 1.
- Maintenance-free Design: Adopting lead-acid valve-regulated sealed technology (VRLA), the sealed design avoids electrolyte leakage and corrosion risks, and eliminates the need for daily maintenance such as adding water, which is convenient to use and ensures the safety and environmental protection of the use environment 2.
Performance Parameters
- Internal Resistance: Low internal resistance, which can reduce energy loss during battery charging and discharging and stabilize discharge performance 2.
- Operating Temperature Range: Adaptable to a wide temperature range, with an operating temperature of -15℃ to 40℃, and can maintain relatively stable performance under different ambient temperatures 2.
Application Fields 5
- UPS Uninterruptible Power Supply: Provide backup power for equipment such as computers and servers, ensuring that the equipment can continue to operate when the mains power fails and protecting data security.
- Communication Systems: Used in communication equipment such as communication base stations, maintaining the normal operation of communication equipment when power is interrupted and ensuring the smoothness of the communication network.
- Medical Equipment: Such as medical monitoring equipment, emergency equipment, etc., providing reliable power support for medical equipment in emergency situations to ensure the normal progress of medical work.
- Emergency Lighting: Used in emergency lighting systems in buildings, public places and other places, providing lighting during power outages or emergencies to ensure safe evacuation of personnel.
- Security Systems: Powering security equipment such as surveillance cameras and alarm devices, ensuring that the security system can operate normally at all times and ensuring safety.
- Other Fields: It can also be applied to fields such as telecommunications, power grids, financial industries, rail transit, petrochemical industry, intelligent manufacturing, automatic control systems, and small and medium-sized enterprise computer rooms.
Usage Notes 1
- If the battery has been stored for three months, it is necessary to replenish its power; if it has been stored for half a year, it is necessary to charge and discharge the battery to complete one cycle.
- During use, never discharge the battery completely before recharging, which will greatly damage the battery. Charge it as you use it until it is fully charged, but do not overcharge or overdischarge either.
- During the handling of the battery, throwing, rolling over and heavy pressing are prohibited.
- Short-circuiting the positive and negative poles of the battery is strictly prohibited.
- The battery should be charged immediately after discharge to restore its capacity. Do not leave it unused for too long (more than 48 hours) after discharge, to prevent the battery from being undercharged and unable to be recharged next time.
- After discharging the battery, long-time charging with a large current (greater than 0.3C₁₀A) is prohibited to prevent the battery from swelling.